Helium leak testing

Helium charged vacuum test[ edit ] In this case the part is pressurized sometime this test is combined with a burst test, i. They are also portable thanks to a special leak detector cart.

The following calculations compare a typical helium leak rate and the required vacuum levels to achieve a low background noise of the tracer gas due to atmospheric concentrations. Pharmaceutical, contract packaging, and medical device companies in thirteen countries around the world are presently employing our testing machines and utilizing our technical support and testing services.

We are able to detect leaks to mbarl-s or equivalent to any other units such a pascal meters cubed per second or ppm etc.

Partial vacuum method ultra sniffer test [ edit ] In contrast to the Helium charged sniffer test, the partial vacuum method, the ultra sniffer test gas method UST-method uses the partial vacuum effect, so that the gas tightness of test sample can be detected at normal pressure with the same sensitivity as the helium charged vacuum test with helium gas helium.

Detect ability sensors or instruments available, and detection limits Suitability of Sensor rugged for production environments Applicable Test Methods influenced by sensors Argon vs. This means that careful engineering of the seals is necessary, particularly where complicated seals are required e.

Helium leak testing is highly accurate and can detect the smallest leaks that other forms of testing such as bubble testing would not be able to find. For more frequent testing, this may mean piping the extracted test gas away to the outside of the building on the downwind side and well clear from doors or windows that could allow it back in.

One does not want to release the test gas into the test area and then affect the results of the next part so either remove the helium to recycle on the next test or purge it outside your building away from any direct path back into your test area. Leak detection personal are qualified to ISO The vacuum system will carry any tracer gas molecule into the analyzer cell of the magnetic sector mass spectrometer.

Finally, you can extract the helium into a vessel scientific equipment is essential so it can be compressed for later use. Here one extracts the helium into an intermediate holding vessel to be compressed back to high pressure to recover the helium.

One can also use these techniques in combination to first detect leakage from the part then sniff to locate the leak. We are able to carry out vacuum helium leak detection on individual components, vessels and tanks etc of varying sizes and volumes either by using the mass spectrometer itself to generate the vacuum in the component if the size allows or with a combination of helium mass spectrometer and auxiliary pumping equipment which we can also supply if required on larger volumes.

Helium Leak Testing Methods There are two primary methods to perform helium leak testing: The helium can cling to various surfaces and affect the results of the test. So, one may need to "wash" away any clinging helium in the chamber and part in a gas containing no helium.

Helium Fine Leak Hermeticity Testing

On rare occasions certifiably pure gas is used. The helium is used as a tracer gas and its concentration is measured. In most helium leak testing applications, one uses a mass spectrometer tuned to detect helium although it is possible to use a residual gas analyser.

If the part under test is filled with helium it is important that the test charge is taken away and not just released into the immediate area. This results in a challenging production environment that would require deeper vacuum levels and longer test cycle times compared to helium.

We can deal with leaks involving all kinds of media, so whether you are searching for vacuum leaks or the loss of pressure in fuel, gas, steam, air, refrigerant, water or oil systems, Severn Vacuum Services Limited can help.

If you shed is big enough and the testing infrequent it may be fine to vent the test gas within the test area. Return to Content Vacuum Helium Leak Detection Helium mass spectrometer leak detection equipment can be used to detect and locate leaks in individual components or up to large scale complicated plant.

Helium Leak Testing

The outer surface of the part to be tested is sprayed with a localized stream of helium tracer gas. We are sometimes able to carry out this procedure on plant that does not normally run under vacuum with the use of a condensing trap and auxiliary pumps with helium mass spectrometer to detect leaks on that plant.

There is approximately 5 ppm Helium in the atmosphere. Our engineers and technicians for Helium Leak Testing are well experienced, qualified, driven for excellence, and are service time attentive.

We carry out vacuum helium leak detection on large plant such as industrial freeze drying equipment, vacuum deposition units and other vacuum plant at customer sites by connecting into existing vacuum system and sampling of process gas with the helium mass spectrometer to detect problem leaks on customer plant.

The mass spectrometer is fitted with a special device, a sniffer probe, that allows it to sample air and tracer gas when confronted with a leak at atmospheric pressure and to bring it into the mass spectrometer.

Our extensive experience in Helium Leak testing is frequently requested by many industries, including: For the embedding of the test samples, a simple plastic bag is sufficient. Of course at high speed the automatic handling of the product and automatic connection play a large part.

Uses[ edit ] Helium mass spectrometer leak detectors are used in production line industries such as refrigeration and air conditioningautomotive parts, carbonated beverage containers food packages and aerosol packaging, as well as in the manufacture of steam products, gas bottlesfire extinguisherstire valves, and numerous other products including all vacuum systems.

However, it is important to realise that most test parts start with being full of air, so by introducing helium into this air it will be diluted. On-site Installation, Validation, and Training services for our helium leak testing units. Helium leak testing is the most reliable and conclusive method of leak detection, in comparison with bubble testing which is suitable for identifying only large leaks and cannot quantify them.

At janettravellmd.com Industrial Services, we offer flexible solutions which can be adapted to our client’s needs. Cincinnati Test - Leak Test Systems | Leak Testing.

Leak Testing Services. HVS Leak Detection has over 25 years of experience finding difficult to detect leaks.

In shop or on-site, we can quickly locate even the smallest leaks in any pressure system, vacuum system or hermetic system. EB MASS SPECTROMETER HELIUM LEAK TEST PROCEDURE OUTBOARD The purpose of this procedure is to define a method for mass spectrometer helium leak detection of high purity gas distribution components.

Helium leak testing can generally be between one thousand and one million times more sensitive than pressure decay techniques. Acceptance/Commissioning New Construction Precision leak detection should be a part of your pre-acceptance testing for all new construction and upgrades.

Helium hermeticity testing is used to verify the seal process of a hermetic device. Devices are typically preconditioned in a pressurized chamber and, after the required conditions are met, the leak rate is measured and recorded, applying pass/fail criteria.

Helium leak testing
Rated 3/5 based on 76 review
Leak Detection - Compliance Testing & Technology